Keysight Technologies (Agilent HP) | 16531A | /list-logic-analyzer/agilent-modules/agilent-hp-16531a | Disc | { "specId": "88", "unit": "", "controlType": "0", "value": "4 ksamples/ch", "colIndex": "4", "specName": "Memory Depth" } | | | | | { "specId": "15", "unit": "", "controlType": "3", "value": "2", "colIndex": "9", "specName": "Channels" } | { "specId": "7", "unit": "Hz", "controlType": "2", "value": "100000000", "colIndex": "10", "specName": "Bandwidth" } | { "specId": "124", "unit": "Sa/sec", "controlType": "2", "value": "400000000", "colIndex": "11", "specName": "Sample Rate" } | | |
Keysight Technologies (Agilent HP) | 16550A | /list-logic-analyzer/state-timing-analysis-modules/agilent-hp-16550a | Disc | { "specId": "88", "unit": "", "controlType": "0", "value": "4 M", "colIndex": "4", "specName": "Memory Depth" } | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "5", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "102", "colIndex": "6", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "100000000", "colIndex": "7", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "500000000", "colIndex": "8", "specName": "Max. Timing Speed" } | | | | | |
Keysight Technologies (Agilent HP) | 16750A | /list-logic-analyzer/agilent-modules/agilent-hp-16750a | Disc | { "specId": "88", "unit": "", "controlType": "0", "value": "4 M", "colIndex": "4", "specName": "Memory Depth" } | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "5", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "68", "colIndex": "6", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "400000000", "colIndex": "7", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "2000000000", "colIndex": "8", "specName": "Max. Timing Speed" } | | | | | |
Keysight Technologies (Agilent HP) | 16910A | /list-logic-analyzer/agilent-modules/agilent-hp-16910a | | { "specId": "88", "unit": "", "controlType": "0", "value": "256 KB up to 32 MB", "colIndex": "4", "specName": "Memory Depth" } | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "5", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "102", "colIndex": "6", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "450000000", "colIndex": "7", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "4000000000", "colIndex": "8", "specName": "Max. Timing Speed" } | | | | { "specId": "104", "unit": "", "controlType": "0", "value": "Memory Depth - 256: 256KB (in base config.); 001: 1MB; 004: 4MB; 016: 16MB; 032: 32MB; State Speed - 250: 250MHz; 500: 450 MHz", "colIndex": "12", "specName": "Options" } | |
Keysight Technologies (Agilent HP) | 16752B | /list-logic-analyzer/agilent-modules/agilent-hp-16752b | Disc | { "specId": "88", "unit": "", "controlType": "0", "value": "64M/32M", "colIndex": "4", "specName": "Memory Depth" } | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "5", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "68", "colIndex": "6", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "400000000", "colIndex": "7", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "800000000", "colIndex": "8", "specName": "Max. Timing Speed" } | | | | | |
Keysight Technologies (Agilent HP) | 16740A | /list-logic-analyzer/state-timing-analysis-modules/agilent-hp-16740a | Disc | { "specId": "88", "unit": "", "controlType": "0", "value": "2M/1M", "colIndex": "4", "specName": "Memory Depth" } | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "5", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "68", "colIndex": "6", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "400000000", "colIndex": "7", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "800000000", "colIndex": "8", "specName": "Max. Timing Speed" } | | | | | |
Keysight Technologies (Agilent HP) | 16717A | /list-logic-analyzer/state-timing-analysis-modules/agilent-hp-16717a | Disc | { "specId": "88", "unit": "", "controlType": "0", "value": "2M/ch", "colIndex": "4", "specName": "Memory Depth" } | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "5", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "68", "colIndex": "6", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "333000000", "colIndex": "7", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "2000000000", "colIndex": "8", "specName": "Max. Timing Speed" } | | | | | |
Keysight Technologies (Agilent HP) | 16532A | /list-logic-analyzer/agilent-modules/agilent-hp-16532a | Disc | { "specId": "88", "unit": "", "controlType": "0", "value": "8000 samples/ch", "colIndex": "4", "specName": "Memory Depth" } | | | | | { "specId": "15", "unit": "", "controlType": "3", "value": "2", "colIndex": "9", "specName": "Channels" } | { "specId": "7", "unit": "Hz", "controlType": "2", "value": "250000000", "colIndex": "10", "specName": "Bandwidth" } | { "specId": "124", "unit": "Sa/sec", "controlType": "2", "value": "1000000000", "colIndex": "11", "specName": "Sample Rate" } | | |
Keysight Technologies (Agilent HP) | 16534A | /list-logic-analyzer/agilent-modules/agilent-hp-16534a | Disc | { "specId": "88", "unit": "", "controlType": "0", "value": "32768 points waveform record length", "colIndex": "4", "specName": "Memory Depth" } | | | | | { "specId": "15", "unit": "", "controlType": "3", "value": "2", "colIndex": "9", "specName": "Channels" } | { "specId": "7", "unit": "Hz", "controlType": "2", "value": "500000000", "colIndex": "10", "specName": "Bandwidth" } | { "specId": "124", "unit": "Sa/sec", "controlType": "2", "value": "2000000000", "colIndex": "11", "specName": "Sample Rate" } | | |
Keysight Technologies (Agilent HP) | U4154A | /list-logic-analyzer/agilent-modules/agilent-hp-u4154a | | { "specId": "88", "unit": "", "controlType": "0", "value": "256 Ksamples (nominal, TimingZoom)", "colIndex": "4", "specName": "Memory Depth" } | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "5", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "136", "colIndex": "6", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "2500000000", "colIndex": "7", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "2500000000", "colIndex": "8", "specName": "Max. Timing Speed" } | | | | { "specId": "104", "unit": "", "controlType": "0", "value": "Memory depths: 2M, 4 M, 16 M, 32 M, 64 M, 128 M, 200 M", "colIndex": "12", "specName": "Options" } | |
Keysight Technologies (Agilent HP) | 16720A | /list-generators/pattern/agilent-hp-16720a | | | | | | | { "specId": "15", "unit": "", "controlType": "3", "value": "48-channels per module, connect up to 5 modules for 240 channels", "colIndex": "9", "specName": "Channels" } | | | | { "specId": "111", "unit": "", "controlType": "0", "value": "Memory depth in vectors: 16 M / 8 M (half / full channel)", "colIndex": "13", "specName": "Pattern Depth" } |