227 Visitors viewed Test Equipment Connection Corp. ads in the last 30 Days
Categories: Test Sets, S-Parameter Test Sets
Manufacturer: Keysight Technologies (Agilent HP)
Model: 8516A
Condition: Used
Seller: Test Equipment Connection Corp.
Keysight (formerly Agilent) 8516A S-Parameter Test Set designed to operate specifically
S-Parameter Test Set designed to operate specifically with the Agilent-HP 8510 Network Analyzer.Serveral S-parameter test sets are available for the Agilent-Hp 8510B network analyzer for broadband coaxial measurements from 45 MHz to 40 GHz. The Agilent-Hp 8514B, 8515A, and 8516A test sets have a dual port architecture which develops a separate reference channel for each incident port. RF switching is done with a single buikt-in electronic switch. For active device measurements, the test sets include the ability to apply DC bias (external) to the test port center conductors. Also available are two 90 dB step attenuators (60dB in the 8516A) which allow control of the port 1 and port 2 signal levels.Options:Opt. 001 = Adds IF switchingOpt. 002 = Deletes step attenuators and bias teesOpt. 003 = High forward dynamic rangeRefurbished
The HP 8516A is an S-parameter test set for the 8510B.
The 8516A test set has a dual port architecture, which develops a separate reference channel for each incident port. RF switching is done with a single built-in electronic switch. For active device measurements, the test sets include the ability to apply DC bias (external) to the test port center conductors. Also available are two 60 dB step attenuators, which allow control of the port 1 and port 2 signal levels.
The 8516A test set is coupler-based. Two alternate coupler configurations are available. The standard configuration is symmetrical and has identical dynamic range performance in both forward and reverse transmission measurements. The port 1 step attenuator allows reduction of the port 1 output power for forward measurements, and the port 2 attenuator allows reduction of the port 2 output power for reverse measurements.
With the Option 003 configuration, the port 2 coupler is reversed. For forward measurements, the port 2 signal is sampled directly through the main arm of the port 2 coupler. Since coupling loss is removed, dynamic range is increased in the forward direction. Since the port 2 step attenuator is inline with the port 2 sample, the power incident on port 2 may be reduced. With Option 003, up to 1 W may be input into port 2.
Seller Valuetronics International Inc
Seller Test Equipment Experts
Seller Liberty Test Equipment, Inc.
Seller Testwall Ltd
Seller Alltest
Seller NSCA Technologies LLC
Seller Eglink System
Used-Line Dealer since : 2000
Company info
We are specialized in
Our Services
Our Sales Policy
Disributor of
Use this form to contact a dealer from the Dealer Directory. You may contact up to 10 Dealers per day. Please note: Contact forms are monitored for spam. Users who send spam will be blocked from Used-Line.
To:
Remember me
*Contact name, email and message are required.
Product Specs
(From Used-Line T&M Specifications)
Agilent 8516A
Description: