BrandModelModelUrlStatusDynamic RangeWavelengths [nm]Max Pulse WidthMin.Pulse WidthDistance Range Max.Distance Range Min.Distance Resolution
AnritsuMW9076B1/list-fiber-optics/otdr/anritsu-mw9076b1Disc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "40.5", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.00000001", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "400000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "1000", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "1 m ± 3 X measurement distance", "colIndex": "10", "specName": "Distance Resolution" }
AnritsuMW9060A/list-fiber-optics/otdr/anritsu-mw9060aDisc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "34", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.000002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.00000001", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "250000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "10000", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "10 cm to 50 m", "colIndex": "10", "specName": "Distance Resolution" }
AnritsuMW9076B/list-fiber-optics/otdr/anritsu-mw9076bDisc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "45", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.00000001", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "400000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "1000", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "1 m ± 3 X measurement distance", "colIndex": "10", "specName": "Distance Resolution" }
AnritsuMW9076C/list-fiber-optics/otdr/anritsu-mw9076cDisc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "41.5", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550,1625", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.00000001", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "400000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "1000", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "1 m ± 3 X measurement distance", "colIndex": "10", "specName": "Distance Resolution" }
AnritsuMW9076J/list-fiber-optics/otdr/anritsu-mw9076jDisc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "45", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "850", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.0000001", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.00000001", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "100000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "1000", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "1 m ± 3 X measurement distance", "colIndex": "10", "specName": "Distance Resolution" }
EXFOFTB-7300D-002B/list-fiber-optics/otdr/exfo-ftb-7300d-002b{ "specId": "28", "unit": "dB", "controlType": "2", "value": "38", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "260000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "1250", "colIndex": "9", "specName": "Distance Range Min." }
Fluke NetworksOFTM-5610/list-fiber-optics/otdr/fluke-networks-oftm-5610Disc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "52", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "850,1300", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00000065", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000004", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "4000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "0.7", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "1 m ± 0.005% of distance ± 50% of resolution", "colIndex": "10", "specName": "Distance Resolution" }
Fluke NetworksOFTM-5611/list-fiber-optics/otdr/fluke-networks-oftm-5611Disc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "52", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "850,1300", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00000065", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000004", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "4000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "0.7", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "1 m ± 0.005% of distance ± 50% of resolution", "colIndex": "10", "specName": "Distance Resolution" }
Fluke NetworksOFTM-5612/list-fiber-optics/otdr/fluke-networks-oftm-5612Disc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "52", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "850,1300", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00000065", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000004", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "4000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "0.7", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "1 m ± 0.005% of distance ± 50% of resolution", "colIndex": "10", "specName": "Distance Resolution" }
Fluke NetworksOFTM-5630/list-fiber-optics/otdr/fluke-networks-oftm-5630Disc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "60", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.000001", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000008", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "15000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "2.5", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "1 m ± 0.005% of distance ± 50% of resolution", "colIndex": "10", "specName": "Distance Resolution" }
Fluke NetworksOFTM-5631/list-fiber-optics/otdr/fluke-networks-oftm-5631Disc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "60", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.000001", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000008", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "15000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "2.5", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "1 m ± 0.005% of distance ± 50% of resolution", "colIndex": "10", "specName": "Distance Resolution" }
Fluke NetworksOFTM-5632/list-fiber-optics/otdr/fluke-networks-oftm-5632Disc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "60", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.000001", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000008", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "15000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "2.5", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "1 m ± 0.005% of distance ± 50% of resolution", "colIndex": "10", "specName": "Distance Resolution" }
NetTestCMA 8800 - 4439/list-fiber-optics/otdr/nettest-cma-8800-4439Disc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "43", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "250000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "3", "colIndex": "9", "specName": "Distance Range Min." }
NetTestCMA4500/list-fiber-optics/otdr/nettest-cma4500Disc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "50", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310, 1383, 1490, 1550, 1625", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "250000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "10", "colIndex": "9", "specName": "Distance Range Min." }
Keysight Technologies (Agilent HP)N3910AL/list-fiber-optics/otdr/agilent-hp-n3910alDisc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "45", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.00000001", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "26", "unit": "", "controlType": "0", "value": "8 cm", "colIndex": "10", "specName": "Distance Resolution" }
Keysight Technologies (Agilent HP)N3910AM/list-fiber-optics/otdr/agilent-hp-n3910amDisc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "40", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.00000001", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "26", "unit": "", "controlType": "0", "value": "8 cm", "colIndex": "10", "specName": "Distance Resolution" }
Keysight Technologies (Agilent HP)N3911AL/list-fiber-optics/otdr/agilent-hp-n3911alDisc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "43", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1550,1625", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.00000001", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "26", "unit": "", "controlType": "0", "value": "8 cm", "colIndex": "10", "specName": "Distance Resolution" }
Keysight Technologies (Agilent HP)N3914AL/list-fiber-optics/otdr/agilent-hp-n3914alDisc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "43", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550,1625", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.00000001", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "26", "unit": "", "controlType": "0", "value": "8 cm", "colIndex": "10", "specName": "Distance Resolution" }
Keysight Technologies (Agilent HP)E6000C/list-fiber-optics/otdr/agilent-hp-e6000cDisc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "30", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00001", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.00000001", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "26", "unit": "", "controlType": "0", "value": "4 cm", "colIndex": "10", "specName": "Distance Resolution" }
Keysight Technologies (Agilent HP)E6003A/list-fiber-optics/otdr/agilent-hp-e6003aDisc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "35", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00001", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.00000001", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "26", "unit": "", "controlType": "0", "value": "4 cm", "colIndex": "10", "specName": "Distance Resolution" }
Keysight Technologies (Agilent HP)E6003B/list-fiber-optics/otdr/agilent-hp-e6003bDisc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "40", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.00000001", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "26", "unit": "", "controlType": "0", "value": "4 cm", "colIndex": "10", "specName": "Distance Resolution" }
Keysight Technologies (Agilent HP)E6003C/list-fiber-optics/otdr/agilent-hp-e6003cDisc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "43", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "26", "unit": "", "controlType": "0", "value": "4 cm", "colIndex": "10", "specName": "Distance Resolution" }
Keysight Technologies (Agilent HP)E6004A/list-fiber-optics/otdr/agilent-hp-e6004aDisc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "30", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00001", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.00000001", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "26", "unit": "", "controlType": "0", "value": "4 cm", "colIndex": "10", "specName": "Distance Resolution" }
Keysight Technologies (Agilent HP)E6005A/list-fiber-optics/otdr/agilent-hp-e6005aDisc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "34", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "850,1300", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00001", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "26", "unit": "", "controlType": "0", "value": "4 cm", "colIndex": "10", "specName": "Distance Resolution" }
Keysight Technologies (Agilent HP)E6008B/list-fiber-optics/otdr/agilent-hp-e6008bDisc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "45", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.00000001", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "26", "unit": "", "controlType": "0", "value": "4 cm", "colIndex": "10", "specName": "Distance Resolution" }
Keysight Technologies (Agilent HP)E6009A/list-fiber-optics/otdr/agilent-hp-e6009aDisc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "23", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "850,1300", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.000001", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "26", "unit": "", "controlType": "0", "value": "4 cm", "colIndex": "10", "specName": "Distance Resolution" }
Keysight Technologies (Agilent HP)E6012A/list-fiber-optics/otdr/agilent-hp-e6012aDisc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "43", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1550,1625", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.00000001", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "26", "unit": "", "controlType": "0", "value": "4 cm", "colIndex": "10", "specName": "Distance Resolution" }
Keysight Technologies (Agilent HP)E6013A/list-fiber-optics/otdr/agilent-hp-e6013aDisc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "39", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550,1625", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.00000001", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "26", "unit": "", "controlType": "0", "value": "4 cm", "colIndex": "10", "specName": "Distance Resolution" }
Keysight Technologies (Agilent HP)E6020B-011/list-fiber-optics/otdr/agilent-hp-e6020b-011Disc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "30", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00001", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.00000001", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "26", "unit": "", "controlType": "0", "value": "4 cm", "colIndex": "10", "specName": "Distance Resolution" }
Keysight Technologies (Agilent HP)E6020B-012/list-fiber-optics/otdr/agilent-hp-e6020b-012Disc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "30", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00001", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.00000001", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "26", "unit": "", "controlType": "0", "value": "4 cm", "colIndex": "10", "specName": "Distance Resolution" }
Keysight Technologies (Agilent HP)E6020B-013/list-fiber-optics/otdr/agilent-hp-e6020b-013Disc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "30", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "850,1300,1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00001", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.00000001", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "26", "unit": "", "controlType": "0", "value": "4 cm", "colIndex": "10", "specName": "Distance Resolution" }
Keysight Technologies (Agilent HP)E6020B-014/list-fiber-optics/otdr/agilent-hp-e6020b-014Disc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "23", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "850,1300", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00001", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.00000001", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "26", "unit": "", "controlType": "0", "value": "4 cm", "colIndex": "10", "specName": "Distance Resolution" }
Keysight Technologies (Agilent HP)E4310A/list-fiber-optics/otdr/agilent-hp-e4310aDisc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "40", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550,1625", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00001", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.00000001", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "500000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "1000", "colIndex": "9", "specName": "Distance Range Min." }
Fluke NetworksOFTM-5610B/list-fiber-optics/otdr/fluke-networks-oftm-5610b{ "specId": "28", "unit": "dB", "controlType": "2", "value": "15", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "850,1300", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00000065", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000004", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "7000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "26", "unit": "", "controlType": "0", "value": "3 cm to 50 cm", "colIndex": "10", "specName": "Distance Resolution" }
Fluke NetworksOFTM-5611B/list-fiber-optics/otdr/fluke-networks-oftm-5611b{ "specId": "28", "unit": "dB", "controlType": "2", "value": "15", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "850,1300", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00000065", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000004", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "7000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "26", "unit": "", "controlType": "0", "value": "3 cm to 50 cm", "colIndex": "10", "specName": "Distance Resolution" }
Fluke NetworksOFTM-5730/list-fiber-optics/otdr/fluke-networks-oftm-5730{ "specId": "28", "unit": "dB", "controlType": "2", "value": "26", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00001", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "60000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "26", "unit": "", "controlType": "0", "value": "3 cm to 400 cm", "colIndex": "10", "specName": "Distance Resolution" }
Fluke NetworksOFTM-5731/list-fiber-optics/otdr/fluke-networks-oftm-5731{ "specId": "28", "unit": "dB", "controlType": "2", "value": "26", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00001", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "60000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "26", "unit": "", "controlType": "0", "value": "3 cm to 400 cm", "colIndex": "10", "specName": "Distance Resolution" }
Fluke NetworksOFTM-5732/list-fiber-optics/otdr/fluke-networks-oftm-5732{ "specId": "28", "unit": "dB", "controlType": "2", "value": "26", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00001", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "60000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "26", "unit": "", "controlType": "0", "value": "3 cm to 400 cm", "colIndex": "10", "specName": "Distance Resolution" }
AnritsuMT9083A-057/list-fiber-optics/otdr/anritsu-mt9083a-057{ "specId": "28", "unit": "dB", "controlType": "2", "value": "36", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550,1625", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "200000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "500", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "From 5 cm", "colIndex": "10", "specName": "Distance Resolution" }
AnritsuMT9083A-058/list-fiber-optics/otdr/anritsu-mt9083a-058{ "specId": "28", "unit": "dB", "controlType": "2", "value": "34", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1490,1550,1625", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "200000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "500", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "From 5 cm", "colIndex": "10", "specName": "Distance Resolution" }
AnritsuMT9083A-059/list-fiber-optics/otdr/anritsu-mt9083a-059{ "specId": "28", "unit": "dB", "controlType": "2", "value": "34", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1383,1550,1625", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "200000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "500", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "From 5 cm", "colIndex": "10", "specName": "Distance Resolution" }
AnritsuMT9083A-060/list-fiber-optics/otdr/anritsu-mt9083a-060{ "specId": "28", "unit": "dB", "controlType": "2", "value": "36.5", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1490", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "200000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "500", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "From 5 cm", "colIndex": "10", "specName": "Distance Resolution" }
AnritsuMT9083A-061/list-fiber-optics/otdr/anritsu-mt9083a-061{ "specId": "28", "unit": "dB", "controlType": "2", "value": "33.5", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1625", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "200000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "500", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "From 5 cm", "colIndex": "10", "specName": "Distance Resolution" }
AnritsuMT9083A-062/list-fiber-optics/otdr/anritsu-mt9083a-062{ "specId": "28", "unit": "dB", "controlType": "2", "value": "8", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "780", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00000001", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "2500", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "500", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "From 5 cm", "colIndex": "10", "specName": "Distance Resolution" }
AnritsuMT9083A-063/list-fiber-optics/otdr/anritsu-mt9083a-063{ "specId": "28", "unit": "dB", "controlType": "2", "value": "38", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "850,1300,1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "200000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "500", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "From 5 cm", "colIndex": "10", "specName": "Distance Resolution" }
AnritsuMT9083A-064/list-fiber-optics/otdr/anritsu-mt9083a-064{ "specId": "28", "unit": "dB", "controlType": "2", "value": "28", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "850,1300", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.000004", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "100000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "500", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "From 5 cm", "colIndex": "10", "specName": "Distance Resolution" }
AnritsuMT9083A-065/list-fiber-optics/otdr/anritsu-mt9083a-065{ "specId": "28", "unit": "dB", "controlType": "2", "value": "28", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "850", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.0000005", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "100000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "500", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "From 5 cm", "colIndex": "10", "specName": "Distance Resolution" }
AnritsuMT9083A-068/list-fiber-optics/otdr/anritsu-mt9083a-068{ "specId": "28", "unit": "dB", "controlType": "2", "value": "36.5", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "780,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "200000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "500", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "From 5 cm", "colIndex": "10", "specName": "Distance Resolution" }
AnritsuMT9083A-050/list-fiber-optics/otdr/anritsu-mt9083a-050{ "specId": "28", "unit": "dB", "controlType": "2", "value": "38.5", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "200000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "500", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "From 5 cm", "colIndex": "10", "specName": "Distance Resolution" }
AnritsuMT9083A-051/list-fiber-optics/otdr/anritsu-mt9083a-051{ "specId": "28", "unit": "dB", "controlType": "2", "value": "37", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "200000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "500", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "From 5 cm", "colIndex": "10", "specName": "Distance Resolution" }
AnritsuMT9083A-052/list-fiber-optics/otdr/anritsu-mt9083a-052{ "specId": "28", "unit": "dB", "controlType": "2", "value": "33.5", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1650", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "200000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "500", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "From 5 cm", "colIndex": "10", "specName": "Distance Resolution" }
AnritsuMT9083A-053/list-fiber-optics/otdr/anritsu-mt9083a-053{ "specId": "28", "unit": "dB", "controlType": "2", "value": "38", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "200000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "500", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "From 5 cm", "colIndex": "10", "specName": "Distance Resolution" }
AnritsuMT9083A-054/list-fiber-optics/otdr/anritsu-mt9083a-054{ "specId": "28", "unit": "dB", "controlType": "2", "value": "36", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1550,1560", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "200000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "500", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "From 5 cm", "colIndex": "10", "specName": "Distance Resolution" }
AnritsuMT9083A-055/list-fiber-optics/otdr/anritsu-mt9083a-055{ "specId": "28", "unit": "dB", "controlType": "2", "value": "37.5", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550,1650", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "200000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "500", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "From 5 cm", "colIndex": "10", "specName": "Distance Resolution" }
AnritsuMT9083A-056/list-fiber-optics/otdr/anritsu-mt9083a-056{ "specId": "28", "unit": "dB", "controlType": "2", "value": "36", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1490,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "200000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "500", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "From 5 cm", "colIndex": "10", "specName": "Distance Resolution" }
AnritsuMT9090A/list-fiber-optics/otdr/anritsu-mt9090a{ "specId": "28", "unit": "dB", "controlType": "2", "value": "7", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "780,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00000001", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "2500", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "26", "unit": "", "controlType": "0", "value": "5 cm", "colIndex": "10", "specName": "Distance Resolution" }
JDSUT-BERD 6000/list-fiber-optics/otdr/jdsu-t-berd-6000{ "specId": "28", "unit": "dB", "controlType": "2", "value": "50", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310, 1383, 1490, 1550, 1625", "colIndex": "5", "specName": "Wavelengths [nm]" }
NetTestCMA4500-25/list-fiber-optics/otdr/nettest-cma4500-25Disc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "37", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
NetTestCMA4500-35/list-fiber-optics/otdr/nettest-cma4500-35Disc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "40", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
NetTestCMA4500-36/list-fiber-optics/otdr/nettest-cma4500-36Disc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "40", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550,1625", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
NetTestCMA4500-45/list-fiber-optics/otdr/nettest-cma4500-45Disc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "45", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00003", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
NetTestCMA4500-46/list-fiber-optics/otdr/nettest-cma4500-46Disc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "45", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550,1625", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00003", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
NetTestCMA4500-54/list-fiber-optics/otdr/nettest-cma4500-54Disc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "50", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00003", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
NetTestCMA4500-60/list-fiber-optics/otdr/nettest-cma4500-60Disc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "35", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "850,1300,1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
NetTestCMA4500-61/list-fiber-optics/otdr/nettest-cma4500-61Disc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "35", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "850,1300,1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
NetTestCMA4500-62/list-fiber-optics/otdr/nettest-cma4500-62Disc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "40", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "850,1300,1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
NetTestCMA4500-66/list-fiber-optics/otdr/nettest-cma4500-66Disc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "26", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "850,1300", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.000001", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "64000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
NetTestCMA4500-69/list-fiber-optics/otdr/nettest-cma4500-69Disc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "26", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "850,1300", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.000001", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "64000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
NetTestCMA4500-81/list-fiber-optics/otdr/nettest-cma4500-81Disc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "40", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1383,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
NetTestCMA4500-83/list-fiber-optics/otdr/nettest-cma4500-83Disc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "35", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1383,1550,1625", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
NetTestCMA4500-P1/list-fiber-optics/otdr/nettest-cma4500-p1Disc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "40", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1490,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
NetTestCMA4500-P3/list-fiber-optics/otdr/nettest-cma4500-p3Disc{ "specId": "28", "unit": "dB", "controlType": "2", "value": "37", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1490,1550,1625", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
AnritsuCMA5000a/list-fiber-optics/otdr/anritsu-cma5000a{ "specId": "28", "unit": "dB", "controlType": "2", "value": "50", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "850, 1300, 1310, 1383, 1410, 1490, 1550, 1625", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "0.5 meter resolution at 125 km, 1 meter resolution at 250 km", "colIndex": "10", "specName": "Distance Resolution" }
AnritsuCMA5302/list-fiber-optics/otdr/anritsu-cma5302{ "specId": "28", "unit": "dB", "controlType": "2", "value": "37", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550,1625", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "0.0001 km, 0.1 m, 1 ft, 0.0001 mi", "colIndex": "10", "specName": "Distance Resolution" }
AnritsuCMA5266/list-fiber-optics/otdr/anritsu-cma5266{ "specId": "28", "unit": "dB", "controlType": "2", "value": "26", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "850,1300,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.000001", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "64000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
AnritsuCMA5269/list-fiber-optics/otdr/anritsu-cma5269{ "specId": "28", "unit": "dB", "controlType": "2", "value": "26", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "850,1300,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.000001", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "64000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
AnritsuCMA5260/list-fiber-optics/otdr/anritsu-cma5260{ "specId": "28", "unit": "dB", "controlType": "2", "value": "35", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "850,1300,1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
AnritsuCMA5261/list-fiber-optics/otdr/anritsu-cma5261{ "specId": "28", "unit": "dB", "controlType": "2", "value": "35", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "850,1300,1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
AnritsuCMA5262/list-fiber-optics/otdr/anritsu-cma5262{ "specId": "28", "unit": "dB", "controlType": "2", "value": "40", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "850,1300,1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
AnritsuCMA5225/list-fiber-optics/otdr/anritsu-cma5225{ "specId": "28", "unit": "dB", "controlType": "2", "value": "37", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
AnritsuCMA5235/list-fiber-optics/otdr/anritsu-cma5235{ "specId": "28", "unit": "dB", "controlType": "2", "value": "40", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
AnritsuCMA5236/list-fiber-optics/otdr/anritsu-cma5236{ "specId": "28", "unit": "dB", "controlType": "2", "value": "40", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550,1625", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
AnritsuCMA5245/list-fiber-optics/otdr/anritsu-cma5245{ "specId": "28", "unit": "dB", "controlType": "2", "value": "45", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00003", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
AnritsuCMA5246/list-fiber-optics/otdr/anritsu-cma5246{ "specId": "28", "unit": "dB", "controlType": "2", "value": "45", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550,1625", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00003", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
AnritsuCMA5254/list-fiber-optics/otdr/anritsu-cma5254{ "specId": "28", "unit": "dB", "controlType": "2", "value": "50", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00003", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
AnritsuCMA5281/list-fiber-optics/otdr/anritsu-cma5281{ "specId": "28", "unit": "dB", "controlType": "2", "value": "40", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1383,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
AnritsuCMA5283/list-fiber-optics/otdr/anritsu-cma5283{ "specId": "28", "unit": "dB", "controlType": "2", "value": "35", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1383,1550,1625", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
AnritsuCMA5491/list-fiber-optics/otdr/anritsu-cma5491{ "specId": "28", "unit": "dB", "controlType": "2", "value": "40", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1490,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
AnritsuCMA5493/list-fiber-optics/otdr/anritsu-cma5493{ "specId": "28", "unit": "dB", "controlType": "2", "value": "37", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1490,1550,1625", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "5000", "colIndex": "9", "specName": "Distance Range Min." }
JDSUE8146SRL/list-fiber-optics/otdr/jdsu-e8146srl{ "specId": "28", "unit": "dB", "controlType": "2", "value": "40", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "850,1300,1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "380000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "2.6", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "4 cm sampling resolution", "colIndex": "10", "specName": "Distance Resolution" }
JDSUE4118RMA65/list-fiber-optics/otdr/jdsu-e4118rma65{ "specId": "28", "unit": "dB", "controlType": "2", "value": "34", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1650", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "260000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "500", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "4 cm sampling resolution", "colIndex": "10", "specName": "Distance Resolution" }
JDSUE4126MA/list-fiber-optics/otdr/jdsu-e4126ma{ "specId": "28", "unit": "dB", "controlType": "2", "value": "37", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "260000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "500", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "4 cm sampling resolution", "colIndex": "10", "specName": "Distance Resolution" }
JDSUE4136MA/list-fiber-optics/otdr/jdsu-e4136ma{ "specId": "28", "unit": "dB", "controlType": "2", "value": "37", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550,1625", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "260000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "500", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "4 cm sampling resolution", "colIndex": "10", "specName": "Distance Resolution" }
JDSUE4136RMA/list-fiber-optics/otdr/jdsu-e4136rma{ "specId": "28", "unit": "dB", "controlType": "2", "value": "37", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550,1625", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "260000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "500", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "4 cm sampling resolution", "colIndex": "10", "specName": "Distance Resolution" }
JDSUE4123MM/list-fiber-optics/otdr/jdsu-e4123mm{ "specId": "28", "unit": "dB", "controlType": "2", "value": "27", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "850,1300", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.000001", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "260000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "3.25", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "Sampling resolution is 4 cm", "colIndex": "10", "specName": "Distance Resolution" }
JDSUE4146QUAD/list-fiber-optics/otdr/jdsu-e4146quad{ "specId": "28", "unit": "dB", "controlType": "2", "value": "37", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "850,1300,1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "260000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "3.25", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "Sampling resolution is 4 cm", "colIndex": "10", "specName": "Distance Resolution" }
AnritsuMT9083C/list-fiber-optics/otdr/anritsu-mt9083c{ "specId": "28", "unit": "dB", "controlType": "2", "value": "45", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550,1625", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "500", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "Sampling resolution is 5 cm minimum", "colIndex": "10", "specName": "Distance Resolution" }
AnritsuMU909014A/A1/list-fiber-optics/otdr/anritsu-mu909014a-a1{ "specId": "28", "unit": "dB", "controlType": "2", "value": "32.5", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1625,1650", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "250000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "500", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "Sampling resolution is 5 cm minimum", "colIndex": "10", "specName": "Distance Resolution" }
AnritsuMU909014B/14B1/15B/15B1/list-fiber-optics/otdr/anritsu-mu909014b-14b1-15b-15b1{ "specId": "28", "unit": "dB", "controlType": "2", "value": "37", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000005", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "250000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "500", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "Sampling resolution is 5 cm minimum", "colIndex": "10", "specName": "Distance Resolution" }
JDSUE4118RMP65/list-fiber-optics/otdr/jdsu-e4118rmp65{ "specId": "28", "unit": "dB", "controlType": "2", "value": "40", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1650", "colIndex": "5", "specName": "Wavelengths [nm]" }
JDSUE4126MP/list-fiber-optics/otdr/jdsu-e4126mp{ "specId": "28", "unit": "dB", "controlType": "2", "value": "42", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }
JDSUE8140OTDRCWDM1/2/5/list-fiber-optics/otdr/jdsu-e8140otdrcwdm1-2-5{ "specId": "28", "unit": "dB", "controlType": "2", "value": "42", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "200000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "2.6", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "Sampling resolution: 4 cm", "colIndex": "10", "specName": "Distance Resolution" }
YokogawaAQ1200A/list-fiber-optics/otdr/yokogawa-aq1200a{ "specId": "28", "unit": "dB", "controlType": "2", "value": "34", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00001", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "200000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "500", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "Readout resolution: 1 cm minimum", "colIndex": "10", "specName": "Distance Resolution" }
YokogawaAQ1200B/list-fiber-optics/otdr/yokogawa-aq1200b{ "specId": "28", "unit": "dB", "controlType": "2", "value": "33", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1625", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00001", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "200000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "500", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "Readout resolution: 1 cm minimum", "colIndex": "10", "specName": "Distance Resolution" }
YokogawaAQ1200C/list-fiber-optics/otdr/yokogawa-aq1200c{ "specId": "28", "unit": "dB", "controlType": "2", "value": "34", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1650", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00001", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "200000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "500", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "Readout resolution: 1 cm minimum", "colIndex": "10", "specName": "Distance Resolution" }
EXFOFG-750/list-fiber-optics/otdr/exfo-fg-750{ "specId": "28", "unit": "dB", "controlType": "2", "value": "36", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1625,1650", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "26", "unit": "", "controlType": "0", "value": "Maximum sampling resolution: 0.04 m", "colIndex": "10", "specName": "Distance Resolution" }
AnritsuMW9087B/list-fiber-optics/otdr/anritsu-mw9087b{ "specId": "28", "unit": "dB", "controlType": "2", "value": "41", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1650", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "1000", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "Sampling resolution: 0.05 - 60 m", "colIndex": "10", "specName": "Distance Resolution" }
AnritsuMW9087D/list-fiber-optics/otdr/anritsu-mw9087d{ "specId": "28", "unit": "dB", "controlType": "2", "value": "50", "colIndex": "4", "specName": "Dynamic Range" }{ "specId": "148", "unit": "", "controlType": "1", "value": "1550", "colIndex": "5", "specName": "Wavelengths [nm]" }{ "specId": "59", "unit": "sec", "controlType": "2", "value": "0.00002", "colIndex": "6", "specName": "Max Pulse Width" }{ "specId": "96", "unit": "sec", "controlType": "2", "value": "0.000000003", "colIndex": "7", "specName": "Min.Pulse Width" }{ "specId": "24", "unit": "m", "controlType": "2", "value": "300000", "colIndex": "8", "specName": "Distance Range Max." }{ "specId": "25", "unit": "m", "controlType": "2", "value": "1000", "colIndex": "9", "specName": "Distance Range Min." }{ "specId": "26", "unit": "", "controlType": "0", "value": "Sampling resolution: 0.05 - 60 m", "colIndex": "10", "specName": "Distance Resolution" }
JDSUE4126LM/list-fiber-optics/otdr/jdsu-e4126lm{ "specId": "148", "unit": "", "controlType": "1", "value": "1310,1550", "colIndex": "5", "specName": "Wavelengths [nm]" }