Categories: Testers, Hipots
Manufacturer: Compliance West
Model: HT10kVac/dc
Condition: Used
Seller: Calright Instruments
HT-10KVP-AC/DC Compliance West HT-10KVP AC/DC Hipot Tester, 0-10KVac @ 10mA / 0-14KVdc...
Compliance West HT-10KVP AC/DC Hipot Tester, 0-10KVac @ 10mA / 0-14KVdc @ 5 mA. Ships complete with cables, manual, and Calibration Certificate. The instrument is a bench-type Dielectric Withstand Tester with AC or DC Output, designed for laboratory testing of components and insulation systems. It features automatic one button operation, with numerous safety features designed to protect the operator. The dielectric withstand test is a test which is recognized by safety agencies worldwide as a valid criterion of safe assembly of end-use equipment. The HT-10000P is designed as a research instrument to determine the dielectric properties of component assemblies of end-use equipment. It applies a high-voltage potential between Output and Return test leads and monitors Leakage Current and watches for Dielectric Breakdown during the test. To aid in testing, the HT-10000P can be configured with or without voltage ramp time, with or without a test duration timer, and can be set to deliver high voltage after an arc has been detected to pinpoint an area of arcing. Convenience and testing features include: - Voltage ramp, test time and leakage limit are settable. - Voltage ramp and test duration timer are defeatable for specialized testing. - Testing may terminated or continued when a dielectric breakdown is detected. - Test results are determined quickly, without operator intervention. - The HT-10000P allows custom setups for voltage ramp, test time and leakage limit.Condition: Brand NewCall for Availability
Our HT10kVdc standard laboratory tester has DC output. Leakage current limits can be set with the rear panel knob from 0.5mA to 10mA. Normal operation stops testing when a leakage current greater than the set amount or when a dielectric breakdown is encountered. If desired, testing can be set to continue to examine problem areas. Testing will continue until the design current limit of the tester is exceeded; at which time the output voltage will return to zero.Packaged in a 3U enclosure with voltage and current meters. Provided with test leads terminated in alligator clips and a calibration certificate; one year warranty on parts and labor.
Used-Line Dealer since : 2003
Company info
We are specialized in
Our Services
Our Sales Policy
Disributor of
Use this form to contact a dealer from the Dealer Directory. You may contact up to 10 Dealers per day. Please note: Contact forms are monitored for spam. Users who send spam will be blocked from Used-Line.
To:
Remember me
*Contact name, email and message are required.
Product Specs
(From Used-Line T&M Specifications)
Compliance West HT-10KVP-AC/DC
Description: