Keysight Technologies (Agilent HP) | 16517A | /list-logic-analyzer/state-timing-analysis-modules/agilent-hp-16517a | Disc | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "4", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "80", "colIndex": "5", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "1000000000", "colIndex": "6", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "4000000000", "colIndex": "7", "specName": "Max. Timing Speed" } | { "specId": "88", "unit": "", "controlType": "0", "value": "64K", "colIndex": "8", "specName": "Memory Depth" } | |
Keysight Technologies (Agilent HP) | 16550A | /list-logic-analyzer/state-timing-analysis-modules/agilent-hp-16550a | Disc | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "4", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "102", "colIndex": "5", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "100000000", "colIndex": "6", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "500000000", "colIndex": "7", "specName": "Max. Timing Speed" } | { "specId": "88", "unit": "", "controlType": "0", "value": "4 M", "colIndex": "8", "specName": "Memory Depth" } | |
Keysight Technologies (Agilent HP) | 16752A | /list-logic-analyzer/state-timing-analysis-modules/agilent-hp-16752a | Disc | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "4", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "68", "colIndex": "5", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "400000000", "colIndex": "6", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "2000000000", "colIndex": "7", "specName": "Max. Timing Speed" } | { "specId": "88", "unit": "", "controlType": "0", "value": "32 M", "colIndex": "8", "specName": "Memory Depth" } | |
Keysight Technologies (Agilent HP) | 16751A | /list-logic-analyzer/state-timing-analysis-modules/agilent-hp-16751a | Disc | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "4", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "68", "colIndex": "5", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "400000000", "colIndex": "6", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "2000000000", "colIndex": "7", "specName": "Max. Timing Speed" } | { "specId": "88", "unit": "", "controlType": "0", "value": "16 M", "colIndex": "8", "specName": "Memory Depth" } | |
Keysight Technologies (Agilent HP) | 16557D | /list-logic-analyzer/state-timing-analysis-modules/agilent-hp-16557d | Disc | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "4", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "68", "colIndex": "5", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "135000000", "colIndex": "6", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "500000000", "colIndex": "7", "specName": "Max. Timing Speed" } | { "specId": "88", "unit": "", "controlType": "0", "value": "2 M", "colIndex": "8", "specName": "Memory Depth" } | |
Keysight Technologies (Agilent HP) | 16555D | /list-logic-analyzer/state-timing-analysis-modules/agilent-hp-16555d | Disc | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "4", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "68", "colIndex": "5", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "110000000", "colIndex": "6", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "500000000", "colIndex": "7", "specName": "Max. Timing Speed" } | { "specId": "88", "unit": "", "controlType": "0", "value": "2 M", "colIndex": "8", "specName": "Memory Depth" } | |
Keysight Technologies (Agilent HP) | 16554A | /list-logic-analyzer/state-timing-analysis-modules/agilent-hp-16554a | Disc | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "4", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "68", "colIndex": "5", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "70000000", "colIndex": "6", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "250000000", "colIndex": "7", "specName": "Max. Timing Speed" } | { "specId": "88", "unit": "", "controlType": "0", "value": "1 M", "colIndex": "8", "specName": "Memory Depth" } | |
Keysight Technologies (Agilent HP) | 16518A | /list-logic-analyzer/agilent-cards/agilent-hp-16518a | Disc | { "specId": "52", "unit": "", "controlType": "3", "value": "Expansion card", "colIndex": "4", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "80", "colIndex": "5", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "1000000000", "colIndex": "6", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "4000000000", "colIndex": "7", "specName": "Max. Timing Speed" } | { "specId": "88", "unit": "", "controlType": "0", "value": "64 K", "colIndex": "8", "specName": "Memory Depth" } | |
Tektronix | TLA7M4 | /list-logic-analyzer/state-timing-analysis-modules/tektronix-tla7m4 | Disc | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "4", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "136", "colIndex": "5", "specName": "Max. Channels Number" } | | | | |
Keysight Technologies (Agilent HP) | 16950A | /list-logic-analyzer/state-timing-analysis-modules/agilent-hp-16950a | Disc | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "4", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "68", "colIndex": "5", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "600000000", "colIndex": "6", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "4000000000", "colIndex": "7", "specName": "Max. Timing Speed" } | { "specId": "88", "unit": "", "controlType": "0", "value": "256 KB up to 64 MB", "colIndex": "8", "specName": "Memory Depth" } | { "specId": "104", "unit": "", "controlType": "0", "value": "Memory Depth - 256: 256KB (in base config.); 001: 1MB; 004: 4MB; 016: 16MB; 032: 32MB; 064: 64MB", "colIndex": "9", "specName": "Options" } |
Keysight Technologies (Agilent HP) | 16760A | /list-logic-analyzer/state-timing-analysis-modules/agilent-hp-16760a | Disc | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "4", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "34", "colIndex": "5", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "1500000000", "colIndex": "6", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "800000000", "colIndex": "7", "specName": "Max. Timing Speed" } | { "specId": "88", "unit": "", "controlType": "0", "value": "128/64 M", "colIndex": "8", "specName": "Memory Depth" } | |
Keysight Technologies (Agilent HP) | 16754A | /list-logic-analyzer/state-timing-analysis-modules/agilent-hp-16754a | Disc | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "4", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "68", "colIndex": "5", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "600000000", "colIndex": "6", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "1200000000", "colIndex": "7", "specName": "Max. Timing Speed" } | { "specId": "88", "unit": "", "controlType": "0", "value": "8M/4M", "colIndex": "8", "specName": "Memory Depth" } | |
Keysight Technologies (Agilent HP) | 16756A | /list-logic-analyzer/state-timing-analysis-modules/agilent-hp-16756a | Disc | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "4", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "68", "colIndex": "5", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "600000000", "colIndex": "6", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "1200000000", "colIndex": "7", "specName": "Max. Timing Speed" } | { "specId": "88", "unit": "", "controlType": "0", "value": "128M/64M", "colIndex": "8", "specName": "Memory Depth" } | |
Keysight Technologies (Agilent HP) | 16750B | /list-logic-analyzer/state-timing-analysis-modules/agilent-hp-16750b | Disc | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "4", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "68", "colIndex": "5", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "400000000", "colIndex": "6", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "800000000", "colIndex": "7", "specName": "Max. Timing Speed" } | { "specId": "88", "unit": "", "controlType": "0", "value": "8M/4M", "colIndex": "8", "specName": "Memory Depth" } | |
Keysight Technologies (Agilent HP) | 16740A | /list-logic-analyzer/state-timing-analysis-modules/agilent-hp-16740a | Disc | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "4", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "68", "colIndex": "5", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "400000000", "colIndex": "6", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "800000000", "colIndex": "7", "specName": "Max. Timing Speed" } | { "specId": "88", "unit": "", "controlType": "0", "value": "2M/1M", "colIndex": "8", "specName": "Memory Depth" } | |
Keysight Technologies (Agilent HP) | 16741A | /list-logic-analyzer/state-timing-analysis-modules/agilent-hp-16741a | Disc | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "4", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "68", "colIndex": "5", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "400000000", "colIndex": "6", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "800000000", "colIndex": "7", "specName": "Max. Timing Speed" } | { "specId": "88", "unit": "", "controlType": "0", "value": "8M/4M", "colIndex": "8", "specName": "Memory Depth" } | |
Keysight Technologies (Agilent HP) | 16716A | /list-logic-analyzer/state-timing-analysis-modules/agilent-hp-16716a | Disc | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "4", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "68", "colIndex": "5", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "167000000", "colIndex": "6", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "2000000000", "colIndex": "7", "specName": "Max. Timing Speed" } | { "specId": "88", "unit": "", "controlType": "0", "value": "512kb/ch", "colIndex": "8", "specName": "Memory Depth" } | |
Keysight Technologies (Agilent HP) | 16717A | /list-logic-analyzer/state-timing-analysis-modules/agilent-hp-16717a | Disc | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "4", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "68", "colIndex": "5", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "333000000", "colIndex": "6", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "2000000000", "colIndex": "7", "specName": "Max. Timing Speed" } | { "specId": "88", "unit": "", "controlType": "0", "value": "2M/ch", "colIndex": "8", "specName": "Memory Depth" } | |
Keysight Technologies (Agilent HP) | 16710A | /list-logic-analyzer/state-timing-analysis-modules/agilent-hp-16710a | Disc | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "4", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "102", "colIndex": "5", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "100000000", "colIndex": "6", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "500000000", "colIndex": "7", "specName": "Max. Timing Speed" } | { "specId": "88", "unit": "", "controlType": "0", "value": "8kb/ch", "colIndex": "8", "specName": "Memory Depth" } | |
Keysight Technologies (Agilent HP) | 16711A | /list-logic-analyzer/state-timing-analysis-modules/agilent-hp-16711a | Disc | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "4", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "102", "colIndex": "5", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "100000000", "colIndex": "6", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "500000000", "colIndex": "7", "specName": "Max. Timing Speed" } | { "specId": "88", "unit": "", "controlType": "0", "value": "32kb/ch", "colIndex": "8", "specName": "Memory Depth" } | |
Keysight Technologies (Agilent HP) | 16712A | /list-test-and-measurement/modules-miscellaneous/agilent-hp-16712a | Disc | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "4", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "102", "colIndex": "5", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "100000000", "colIndex": "6", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "500000000", "colIndex": "7", "specName": "Max. Timing Speed" } | { "specId": "88", "unit": "", "controlType": "0", "value": "128kb/ch", "colIndex": "8", "specName": "Memory Depth" } | |
Keysight Technologies (Agilent HP) | 16715A | /list-logic-analyzer/state-timing-analysis-modules/agilent-hp-16715a | Disc | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "4", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "68", "colIndex": "5", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "167000000", "colIndex": "6", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "667000000", "colIndex": "7", "specName": "Max. Timing Speed" } | { "specId": "88", "unit": "", "controlType": "0", "value": "2M/ch", "colIndex": "8", "specName": "Memory Depth" } | |
Keysight Technologies (Agilent HP) | 16718A | /list-logic-analyzer/state-timing-analysis-modules/agilent-hp-16718a | Disc | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "4", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "68", "colIndex": "5", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "333000000", "colIndex": "6", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "2000000000", "colIndex": "7", "specName": "Max. Timing Speed" } | { "specId": "88", "unit": "", "controlType": "0", "value": "8M/ch", "colIndex": "8", "specName": "Memory Depth" } | |
Keysight Technologies (Agilent HP) | 16962A | /list-logic-analyzer/state-timing-analysis-modules/agilent-hp-16962a | | { "specId": "52", "unit": "", "controlType": "3", "value": "Module", "colIndex": "4", "specName": "Instrument Type" } | { "specId": "64", "unit": "", "controlType": "2", "value": "68", "colIndex": "5", "specName": "Max. Channels Number" } | { "specId": "80", "unit": "Hz", "controlType": "2", "value": "2000000000", "colIndex": "6", "specName": "Max. State Speed" } | { "specId": "82", "unit": "Hz", "controlType": "2", "value": "2000000000", "colIndex": "7", "specName": "Max. Timing Speed" } | { "specId": "88", "unit": "", "controlType": "0", "value": "4 M", "colIndex": "8", "specName": "Memory Depth" } | { "specId": "104", "unit": "", "controlType": "0", "value": "Memory to 100 M; slot interposer for high-speed memory bus access; probes, cables, and leads; retention modules; software", "colIndex": "9", "specName": "Options" } |