Keysight Technologies (Agilent HP) | 8163A | /list-meters/optical/agilent-hp-8163a | Disc | { "specId": "133", "unit": "", "controlType": "3", "value": "Laser", "colIndex": "4", "specName": "Type" } | | | | | { "specId": "86", "unit": "", "controlType": "1", "value": "dB,dBm,Watt", "colIndex": "9", "specName": "Measurement Units" } |
Keysight Technologies (Agilent HP) | 86120B | /list-meters/optical/agilent-hp-86120b | | { "specId": "133", "unit": "", "controlType": "3", "value": "Laser", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "Maximum safe input level: 18 dBm", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "±3 ppm absolute accuracy", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.00000165", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.0000007", "colIndex": "8", "specName": "Low end wavelength limit" } | { "specId": "86", "unit": "", "controlType": "1", "value": "dBm,Watt", "colIndex": "9", "specName": "Measurement Units" } |
Keysight Technologies (Agilent HP) | 86120C | /list-meters/optical/agilent-hp-86120c | | { "specId": "133", "unit": "", "controlType": "3", "value": "Laser", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "Maximum safe input level: 18 dBm", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "±2 ppm absolute accuracy", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.00000165", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.00000127", "colIndex": "8", "specName": "Low end wavelength limit" } | { "specId": "86", "unit": "", "controlType": "1", "value": "dBm,Watt", "colIndex": "9", "specName": "Measurement Units" } |
Keysight Technologies (Agilent HP) | 86122A | /list-meters/optical/agilent-hp-86122a | Disc | { "specId": "133", "unit": "", "controlType": "3", "value": "Laser", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "Maximum safe input level: 18 dBm", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "±0.2 ppm absolute accuracy", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.00000165", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.00000127", "colIndex": "8", "specName": "Low end wavelength limit" } | { "specId": "86", "unit": "", "controlType": "1", "value": "dBm,Watt", "colIndex": "9", "specName": "Measurement Units" } |
Keysight Technologies (Agilent HP) | N7744A | /list-meters/optical/agilent-hp-n7744a | | { "specId": "133", "unit": "", "controlType": "3", "value": "Fiber Optic", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "-80 dBm to +10 dBm", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "±2.5 % power uncertainty", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.00000165", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.00000125", "colIndex": "8", "specName": "Low end wavelength limit" } | |
Keysight Technologies (Agilent HP) | N7745A | /list-meters/optical/agilent-hp-n7745a | | { "specId": "133", "unit": "", "controlType": "3", "value": "Fiber Optic", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "-80 dBm to +10 dBm", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "±2.5 % power uncertainty", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.00000165", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.00000125", "colIndex": "8", "specName": "Low end wavelength limit" } | |
Anritsu | 50PMC | /list-meters/optical/anritsu-50pmc | | { "specId": "133", "unit": "", "controlType": "3", "value": "Fiber Optic", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "-50 dBm to +27 dBm (CATV)", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "+/- 0.2 dBm", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.00000163", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.00000085", "colIndex": "8", "specName": "Low end wavelength limit" } | { "specId": "86", "unit": "", "controlType": "1", "value": "dBm,Watt", "colIndex": "9", "specName": "Measurement Units" } |
Anritsu | 5P100 | /list-meters/optical/anritsu-5p100 | | { "specId": "133", "unit": "", "controlType": "3", "value": "Fiber Optic", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "+10 to -60 dBm", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "+/- 0.2 dBm", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.00000163", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.00000085", "colIndex": "8", "specName": "Low end wavelength limit" } | { "specId": "86", "unit": "", "controlType": "1", "value": "dBm,Watt", "colIndex": "9", "specName": "Measurement Units" } |
Anritsu | 5P200C | /list-meters/optical/anritsu-5p200c | | { "specId": "133", "unit": "", "controlType": "3", "value": "Fiber Optic", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "+23 to -50 dBm", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "+/- 0.2 dBm", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.00000163", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.00000085", "colIndex": "8", "specName": "Low end wavelength limit" } | { "specId": "86", "unit": "", "controlType": "1", "value": "dBm,Watt", "colIndex": "9", "specName": "Measurement Units" } |
EXFO | EPM-500 | /list-meters/optical/exfo-epm-500 | | { "specId": "133", "unit": "", "controlType": "3", "value": "Fiber Optic", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "10 to -70 dBm", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "± 5 % uncertainty", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.00000165", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.0000008", "colIndex": "8", "specName": "Low end wavelength limit" } | { "specId": "86", "unit": "", "controlType": "1", "value": "dB,dBm,Watt", "colIndex": "9", "specName": "Measurement Units" } |
EXFO | FPM-600 | /list-meters/optical/exfo-fpm-600 | | { "specId": "133", "unit": "", "controlType": "3", "value": "Fiber Optic", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "26 to –70 dBm", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "± 5 % uncertainty", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.00000165", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.0000008", "colIndex": "8", "specName": "Low end wavelength limit" } | { "specId": "86", "unit": "", "controlType": "1", "value": "dB,dBm,Watt", "colIndex": "9", "specName": "Measurement Units" } |
EXFO | FPM-602X | /list-meters/optical/exfo-fpm-602x | | { "specId": "133", "unit": "", "controlType": "3", "value": "Fiber Optic", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "26 to –55 dBm", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "± 5 % uncertainty", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.00000165", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.0000008", "colIndex": "8", "specName": "Low end wavelength limit" } | { "specId": "86", "unit": "", "controlType": "1", "value": "dB,dBm,Watt", "colIndex": "9", "specName": "Measurement Units" } |
EXFO | PM-1100 | /list-meters/optical/exfo-pm-1100 | | { "specId": "133", "unit": "", "controlType": "3", "value": "Fiber Optic", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "20 to –75 dBm", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "± 5 % uncertainty", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.0000017", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.00000075", "colIndex": "8", "specName": "Low end wavelength limit" } | { "specId": "86", "unit": "", "controlType": "1", "value": "dB,dBm,Watt", "colIndex": "9", "specName": "Measurement Units" } |
EXFO | PM-1600 | /list-meters/optical/exfo-pm-1600 | | { "specId": "133", "unit": "", "controlType": "3", "value": "Fiber Optic", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "9 to –80 dBm", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "± 5 % uncertainty", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.0000017", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.0000008", "colIndex": "8", "specName": "Low end wavelength limit" } | { "specId": "86", "unit": "", "controlType": "1", "value": "dB,dBm,Watt", "colIndex": "9", "specName": "Measurement Units" } |
EXFO | PM-1623W | /list-meters/optical/exfo-pm-1623w | | { "specId": "133", "unit": "", "controlType": "3", "value": "Fiber Optic", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "8 to –70 dBm", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "± 5 % uncertainty", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.0000017", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.0000008", "colIndex": "8", "specName": "Low end wavelength limit" } | { "specId": "86", "unit": "", "controlType": "1", "value": "dB,dBm,Watt", "colIndex": "9", "specName": "Measurement Units" } |
EXFO | PPM-350B | /list-meters/optical/exfo-ppm-350b | Disc | { "specId": "133", "unit": "", "controlType": "3", "value": "Fiber Optic", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "25 to -40 dBm", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "0.5 dB power uncertainty at calibrated wavelengths", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.00000155", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.00000131", "colIndex": "8", "specName": "Low end wavelength limit" } | { "specId": "86", "unit": "", "controlType": "1", "value": "dBm", "colIndex": "9", "specName": "Measurement Units" } |
JDSU | OLP-5 | /list-meters/optical/jdsu-olp-5 | | { "specId": "133", "unit": "", "controlType": "3", "value": "Fiber Optic", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "-60 to +5 dBm", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "±5 % intrinsic uncertainty", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.0000016", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.00000078", "colIndex": "8", "specName": "Low end wavelength limit" } | { "specId": "86", "unit": "", "controlType": "1", "value": "dB,dBm", "colIndex": "9", "specName": "Measurement Units" } |
JDSU | OLP-55 (2277/01) | /list-meters/optical/jdsu-olp-55-2277-01 | | { "specId": "133", "unit": "", "controlType": "3", "value": "Fiber Optic", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "-70 dBm to +20 dBm", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "+/- 3% intrinsic uncertainty", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.00000165", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.00000078", "colIndex": "8", "specName": "Low end wavelength limit" } | { "specId": "86", "unit": "", "controlType": "1", "value": "dB,dBm,Watt", "colIndex": "9", "specName": "Measurement Units" } |
EXFO | IQS-1600 | /list-meters/optical/exfo-iqs-1600 | | { "specId": "133", "unit": "", "controlType": "3", "value": "Fiber Optic", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "9 to -85 dBm", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "±5% uncertainty", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.0000017", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.0000008", "colIndex": "8", "specName": "Low end wavelength limit" } | |
EXFO | IQS-1700 | /list-meters/optical/exfo-iqs-1700 | | { "specId": "133", "unit": "", "controlType": "3", "value": "Fiber Optic", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "21 to -53 dBm", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "±5% uncertainty", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.0000017", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.0000008", "colIndex": "8", "specName": "Low end wavelength limit" } | |
ILX Lightwave | FPM-8210 | /list-meters/optical/ilx-lightwave-fpm-8210 | | { "specId": "133", "unit": "", "controlType": "3", "value": "Fiber Optic", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "-70 to +20dBm", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "±2.5%", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.00000165", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.00000085", "colIndex": "8", "specName": "Low end wavelength limit" } | { "specId": "86", "unit": "", "controlType": "1", "value": "dB,dBm,Watt", "colIndex": "9", "specName": "Measurement Units" } |
ILX Lightwave | OMM-6810B | /list-meters/optical/ilx-lightwave-omm-6810b | | { "specId": "133", "unit": "", "controlType": "3", "value": "Laser", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "-85 to +40dBm", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "±3.0%", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.0000017", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.00000035", "colIndex": "8", "specName": "Low end wavelength limit" } | { "specId": "86", "unit": "", "controlType": "1", "value": "dB,dBm,Watt", "colIndex": "9", "specName": "Measurement Units" } |
JDSU | mOPM-A1 | /list-meters/optical/jdsu-mopm-a1 | | { "specId": "133", "unit": "", "controlType": "3", "value": "Fiber Optic", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "-80 dBm to +10 dBm", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "± 2.5% uncertainty at reference condition", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.00000165", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.0000008", "colIndex": "8", "specName": "Low end wavelength limit" } | { "specId": "86", "unit": "", "controlType": "1", "value": "dB,dBm,Watt", "colIndex": "9", "specName": "Measurement Units" } |
JDSU | mOPM-B1 | /list-meters/optical/jdsu-mopm-b1 | | { "specId": "133", "unit": "", "controlType": "3", "value": "Fiber Optic", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "-80 dBm to +10 dBm (extendable to +27 dBm)", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "± 2.5% uncertainty at reference condition", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.0000017", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.00000075", "colIndex": "8", "specName": "Low end wavelength limit" } | { "specId": "86", "unit": "", "controlType": "1", "value": "dB,dBm,Watt", "colIndex": "9", "specName": "Measurement Units" } |
Anritsu | ML9001A | /list-meters/optical/anritsu-ml9001a | Disc | { "specId": "133", "unit": "", "controlType": "3", "value": "Fiber Optic", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "-100 to +20 dBm ", "colIndex": "5", "specName": "Power Range" } | | | | |
JDSU | OLP-34 | /list-meters/optical/jdsu-olp-34 | | { "specId": "133", "unit": "", "controlType": "3", "value": "Fiber Optic", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "-60 to +5 dBm", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "Absolute uncertainty is ± 0.2 dB (± 5%)", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.0000016", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.00000078", "colIndex": "8", "specName": "Low end wavelength limit" } | { "specId": "86", "unit": "", "controlType": "1", "value": "dB,dBm,Watt", "colIndex": "9", "specName": "Measurement Units" } |
JDSU | OLP-35 | /list-meters/optical/jdsu-olp-35 | | { "specId": "133", "unit": "", "controlType": "3", "value": "Fiber Optic", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "-65 to +10 dBm", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "Absolute uncertainty is ± 0.2 dB (± 5%)", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.00000165", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.00000078", "colIndex": "8", "specName": "Low end wavelength limit" } | { "specId": "86", "unit": "", "controlType": "1", "value": "dB,dBm,Watt", "colIndex": "9", "specName": "Measurement Units" } |
JDSU | OLP-38 | /list-meters/optical/jdsu-olp-38 | | { "specId": "133", "unit": "", "controlType": "3", "value": "Fiber Optic", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "-50 to +26 dBm", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "Absolute uncertainty is ± 0.13 dB (± 3%)", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.00000165", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.00000078", "colIndex": "8", "specName": "Low end wavelength limit" } | { "specId": "86", "unit": "", "controlType": "1", "value": "dB,dBm,Watt", "colIndex": "9", "specName": "Measurement Units" } |
JDSU | MP-60 | /list-meters/optical/jdsu-mp-60 | | { "specId": "133", "unit": "", "controlType": "3", "value": "Fiber Optic", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "–50 to +10 dBm (display range is –65 to +10 dBm)", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "Intrinsic uncertainty is ±0.20 dB (±5%)", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.00000165", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.00000078", "colIndex": "8", "specName": "Low end wavelength limit" } | { "specId": "86", "unit": "", "controlType": "1", "value": "dB,dBm,Watt", "colIndex": "9", "specName": "Measurement Units" } |
JDSU | MP-80 | /list-meters/optical/jdsu-mp-80 | | { "specId": "133", "unit": "", "controlType": "3", "value": "Fiber Optic", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "–35 to +23 dBm (display range is –50 to +26 dBm)", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "Intrinsic uncertainty is ±0.20 dB (±5%)", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.00000165", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.00000078", "colIndex": "8", "specName": "Low end wavelength limit" } | { "specId": "86", "unit": "", "controlType": "1", "value": "dB,dBm,Watt", "colIndex": "9", "specName": "Measurement Units" } |
EXFO | EPM-50 | /list-meters/optical/exfo-epm-50 | | { "specId": "133", "unit": "", "controlType": "3", "value": "Fiber Optic", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "EPM-53: 10 to -60 dBm, EPM-53X: 26 to -50 dBm", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "Power uncertainty is ±5 %", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.00000155", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.00000085", "colIndex": "8", "specName": "Low end wavelength limit" } | { "specId": "86", "unit": "", "controlType": "1", "value": "dB,dBm,Watt", "colIndex": "9", "specName": "Measurement Units" } |
EXFO | IQS-1500 | /list-meters/optical/exfo-iqs-1500 | | { "specId": "133", "unit": "", "controlType": "3", "value": "Fiber Optic", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "+5 to —60 dBm", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "0.9%, 2%, or 3% uncertainty, depending on model, wavelength", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.0000018", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.00000075", "colIndex": "8", "specName": "Low end wavelength limit" } | |
Keysight Technologies (Agilent HP) | 86122B | /list-meters/optical/agilent-hp-86122b | | { "specId": "133", "unit": "", "controlType": "3", "value": "Laser", "colIndex": "4", "specName": "Type" } | { "specId": "114", "unit": "", "controlType": "0", "value": "Maximum safe input level: +18 dBm", "colIndex": "5", "specName": "Power Range" } | { "specId": "1", "unit": "", "controlType": "0", "value": "±0.2 ppm absolute accuracy", "colIndex": "6", "specName": "Accuracy" } | { "specId": "47", "unit": "m", "controlType": "2", "value": "0.00000165", "colIndex": "7", "specName": "High End Wavelength Limit" } | { "specId": "57", "unit": "m", "controlType": "2", "value": "0.00000127", "colIndex": "8", "specName": "Low end wavelength limit" } | { "specId": "86", "unit": "", "controlType": "1", "value": "dBm,Watt", "colIndex": "9", "specName": "Measurement Units" } |