IN STOCK
Categories: Adapters, Miscellaneous Adapters
Manufacturer: Keysight Technologies (Agilent HP)
Model: 83205A
Condition: Used
Seller: Ceyuan Electronic Intrument Co., Ltd
Status Discontinued by Manufacturer The HP 83205A Cellular Adapter is an accessory to...
Condition: GoodStatus Discontinued by ManufacturerThe HP 83205A Cellular Adapter is an accessory to the HP 8921A Cell Site Test Set. The Cellular Adapter and Test Set are connected together via front-panel and rear-panel cables and work together to form a Test System. The Cellular Adapter adds digital signal generation and analysis to the analog test capabilities of the Test Set.The 83205A Cellular Adapter can be configured as one of three different options.83205A CDMA Cellular Adapter, Option 001 83205A CDPD Cellular Adapter, Option 002 83205A CDMA/CDPD Cellular Adapter, Option 003The 83205A CDMA Cellular Adapter (Option 001) and the 83205A CDMA/CDPD Cellular Adapter (Option 003) include DSP (Digital Signal Processing) hardware and firmware to test the transmitter and receiver portions of Code Division Multiple Access (CDMA) base stations. Systems using the CDMA format use encoders and decoders to digitize speech and add call processing information. The 83205A CDPD Cellular Adapter (Option 002) and the 83205A CDMA/CDPD Cellular Adapter (Option 003) include Cellular Digital Packet Data (CDPD) digital signal generation and analysis. The CDPD assembly found in Cellular Adapter Options 002 and 003 provides the hardware and firmware to perform CDPD protocol processing.83205A CDMA specifications:Signal generatorFrequency range: 824 to 894 MHz Resolution: 1 Hz Output level range at Test Set RF IN/OUT: -19 dBm to -137 dBm Output level range at Test Set DUPLEX OUT: +4 dBm to -127 dBmModulationReverse Link Source Modulation: OQPSK per TIA IS-95 Reverse Link Source Modulation Data: Internal data buffer, Idle (all zeroes) Forward Link Source Modulation: QPSK per TIA IS-95 Forward Link Source Modulation Data: Internal (Pilot channel) Residual Rho (?): 0.96 Carrier Feedthrough: -30dBc Adjacent Channel Noise: -45dBc PN Offset: Adjustable from 0 to 511 units (1 unit equals 64 chips) PN Offset Resolution: 0.0156 units (1 chip)Data bufferSize: 5400 frames Modes: Single, Continuous Looping, and Idle Coding: IS-95 CDMA full rate reverse link channel coding, interleaving, and spreading Long Code Mask: 42 zeros Input Data Rate: 9600 bps; 14,400 bps Data Source: For each rate set, 300 frames factory loaded, 1800 frames additional user definable data can be entered via HP-IBAnalyzerOutput level range at Test Set RF IN/OUT: -10 dBm to +48 dBm Output level range at Test Set ANT IN: -46 dBm to +17 dBm Input Frequency Range: 4 MHz to 1000 MHz Rho (?) Measurement Interval Range: 0.25 to 1.25 ms Rho (?) Measurement Range: 0.50 to 1.00Average power measurementInput Frequency Range: 30 MHz to 1000 MHz at RF IN/OUT only Measurement Period: 0.25 ms to 5 ms Measurement Bandwidth: Provides an accurate measure of the total power for signals within 2 MHz of the operating frequency. If other signals are present outside this frequency range, reduced measurement accuracy will result Maximum Input Level: 60 W continuous Measurement Range: 1 mW to 60 W continuous (0 to +48 dBm)Code domain analyzerInput Frequency Range: 4 MHz to 1000 MHz Input Level Range at Test Set RF IN/OUT: Input Level Range:-10 dBm to +48 dBm Input Level Range at Test Set ANT IN: Input Level Range: -46 dBm to +17 dBm Measurement Dynamic Range: 40 dBMeasurement Resolution: 0.01 dB83205A CDPD signal generator specifications: Some specifications (not shown below) are the same as for the 8921A Test Set. (The CDPD Analyzer frequency range and input level range are also the same as for the 8921A Test Set.)Spectral puritySpurious Signals, Adjacent Channels: <-26 dBc Spurious Signals, First Alternate Channel: <-45 dBc Spurious Signals, Second Alternate Channel: <-60 dBcSwitching Speed: Typically <150 ms to be within 1 kHz Transmitter On/Off Level and Timing: >15 dB down in <1 ms Modulation Type: GMSK with BT = 0.5In stock
The HP 83205A Cellular Adapter is an accessory to the HP 8921A Cell Site Test Set. The Cellular Adapter and Test Set are connected together via front-panel and rear-panel cables and work together to form a Test System. The Cellular Adapter adds digital signal generation and analysis to the analog test capabilities of the Test Set.
The 83205A Cellular Adapter can be configured as one of three different options.
The 83205A CDMA Cellular Adapter (Option 001) and the 83205A CDMA/CDPD Cellular Adapter (Option 003) include DSP (Digital Signal Processing) hardware and firmware to test the transmitter and receiver portions of Code Division Multiple Access (CDMA) base stations. Systems using the CDMA format use encoders and decoders to digitize speech and add call processing information. The 83205A CDPD Cellular Adapter (Option 002) and the 83205A CDMA/CDPD Cellular Adapter (Option 003) include Cellular Digital Packet Data (CDPD) digital signal generation and analysis. The CDPD assembly found in Cellular Adapter Options 002 and 003 provides the hardware and firmware to perform CDPD protocol processing.
83205A CDMA specifications:
83205A CDPD signal generator specifications: Some specifications (not shown below) are the same as for the 8921A Test Set. (The CDPD Analyzer frequency range and input level range are also the same as for the 8921A Test Set.)
Seller Test Equipment Experts
Seller Testwall Ltd
Seller NSCA Technologies LLC
Used-Line Dealer since : 2018
Company info
We are specialized in
Our Services
Our Sales Policy
Disributor of
Use this form to contact a dealer from the Dealer Directory. You may contact up to 10 Dealers per day. Please note: Contact forms are monitored for spam. Users who send spam will be blocked from Used-Line.
To:
Remember me
*Contact name, email and message are required.
Product Specs
(From Used-Line T&M Specifications)
Keysight Technologies (Agilent HP) 83205A
Description: